Meter (3-Phase)

Purpose

Measure voltages and currents of 3-phase system

Library

Electrical / Meters

Description

../../_images/meter_3ph.svg

The meter block acts as a set of volt- and ammeters. Voltages can be measured from line to ground (\(V_a\), \(V_b\) and \(V_c\)) or from line to line (\(V_{ab}\), \(V_{bc}\), \(V_{ca}\)) depending on the Voltage measurement parameter. The output for voltage and current is a vectorized signal with three elements.

Parameters

Voltage measurement

Determine whether the voltages are measured from line to ground or from line to line.

Probe Signals

Measured voltage

The measured voltages as a vector with three elements.

Measured current

The measured currents as a vector with three elements.