Dynamic Signal Selector
Purpose
Select or reorder elements from vectorized signal depending on control signal.
Library
System
Description
The block generates an output vector signal that consists of the specified elements of the input vector signal. The elements can be dynamically selected with the control input.
See also the Signal Selector block.
Parameters
- Default index
The default element if the control signal is out of range.
- Indexing
Choose whether the elements from the input vector are selected using 0-based or 1-based indexing.
Probe Signals
- Input
The block input signal.
- Output
The block output signal.
- Switch position
The state of the switch position. This is the control signal or, in case the control signal is out of range, the default index.
- Out of range