GTO (Reverse Conducting)

Purpose

Ideal GTO with ideal anti-parallel diode

Library

Electrical / Power Semiconductors

Description

../../_images/gtodiode.svg

This model of a Gate Turn Off Thyristor has an integrated anti-parallel diode. The diode is usually included in power GTO packages.

Parameters

The following parameters may either be scalars or vectors corresponding to the implicit width of the component:

Initial conductivity

Initial conduction state of the GTO. The GTO is initially blocking if the parameter evaluates to zero, otherwise it is conducting.

Thermal description

Switching losses, conduction losses and thermal equivalent circuit of the component. For more information see chapters Thermal Modeling and Losses of Semiconductor Switch with Diode.

Thermal interface resistance

The thermal resistance of the interface material between case and heat sink, in \((\mathrm{K}/\mathrm{W})\). The default is 0.

Initial temperature

This parameter is used only if the device has an internal thermal impedance and specifies the temperature of the thermal capacitance at the junction at simulation start. The temperatures of the other thermal capacitances are initialized based on a thermal “DC” analysis. If the parameter is left blank, all temperatures are initialized from the external temperature. See also Temperature Initialization.

Probe Signals

Device voltage

The voltage measured between anode and cathode.

Device current

The current through the device flowing from anode to cathode.

Device gate signal

The gate input signal of the device.

Device conductivity

Conduction state of the internal switch. The signal outputs \(0\) when the device is blocking, and \(1\) when it is conducting.

Device junction temperature

Temperature of the first thermal capacitor in the equivalent Cauer network.

Device conduction loss

Continuous thermal conduction losses in watts \((\mathrm{W})\). Only defined if the component is placed on a heat sink.

Device switching loss

Instantaneous thermal switching losses in joules \((\mathrm{J})\). Only defined if the component is placed on a heat sink.